SLA-Backed Annual Maintenance Contracts Across India

Comprehensive Solar O&M & Performance Services

From preventive field care and annual maintenance contracts to live SCADA tracking and AI-powered fault isolation—engineered to safeguard your 25-year solar ROI.

Technical Service Architecture

Explore Every Pillar of Our Solar Care

Select a capability below to inspect deliverables, testing protocols, and SLA commitments.

Core Field Operations

Solar Operations & Maintenance (O&M) Services

Our certified technicians execute disciplined electrical, mechanical, and civil maintenance routines tailored to Indian dust, heat, and monsoon conditions—keeping your modules spotless and inverters running at peak conversion efficiency.

  • ✓Scientific Module Cleaning: Soft-bristle & low-TDS deionized washing timed to minimize thermal shock and soiling loss.
  • ✓Inverter & ACDB/DCDB Servicing: Filter cleaning, thermal scanning of lugs/busbars, SPD inspection, and firmware updates.
  • ✓Earthing & Lightning Protection: Periodic earth-pit resistance testing and lightning arrestor continuity audits.
  • ✓Rapid Corrective Dispatch: Root-cause breakdown repair with OEM warranty claim coordination.
Book an O&M Site Inspection
Solar O&M Field Inspection
Worry-Free Asset Protection

Annual Maintenance Contracts (AMC)

Lock in fixed annual operational costs with clearly defined Performance Ratio (PR) targets, guaranteed response windows, and transparent spares governance.

  • ✓Flexible Coverage Models: Choose Comprehensive (with consumables/spares) or Non-Comprehensive labor + monitoring AMC.
  • ✓Guaranteed Availability SLA: Contractual uptime commitments backed by monthly performance scorecards.
  • ✓Statutory & CEIG Support: Documentation assistance for electrical safety inspections and DISCOM net-metering audits.
  • ✓Dedicated Account Engineer: Single point of contact for multi-site corporate portfolios.
Jump to AMC Tier Comparison
Utility solar park under AMC contract
24/7 Cloud Visibility

Live Solar Plant Monitoring & Performance Tracking

Stop waiting for monthly electricity bills to discover an inverter tripped two weeks ago. Averon aggregates live telemetry across your entire fleet into one crisp dashboard.

  • ✓Real-Time kW, PR & CUF Tracking: Live comparison against weather-corrected expected generation curves.
  • ✓String-Level Health Heatmaps: Spot voltage imbalance, fuse blows, or shading instantly.
  • ✓Multi-Inverter Aggregation: Unified monitoring even if your site uses mixed inverter OEMs.
  • ✓Instant Alert Routing: Automated SMS, WhatsApp, and email escalations for grid outages or trip events.
Launch Interactive Live Demo

Unified Telemetry Stack

Compatible with Modbus RTU/TCP, RS485 dataloggers, WMS pyranometers, and bidirectional ABT meters.

Data Polling Interval
Every 60 Seconds
Alert Escalation Latency
< 3 Minutes
Historical Retention
25-Year Lifecycle Archive
Zero Guesswork Governance

Automated Reporting & Preventive Maintenance

Every inspection, cleaning cycle, and kilowatt-hour is documented automatically—giving CFOs, plant managers, and investors crystal-clear auditability.

  • ✓Automated Daily & Monthly PDF Digests: Scheduled inbox delivery with yield trends, PR benchmarks, and savings in INR.
  • ✓Digital Preventive Checklists: 45-point monthly and quarterly SOPs verified with timestamped site photos.
  • ✓Loss Waterfall Attribution: Separate grid outage losses, soiling losses, and equipment downtime clearly.
Request Sample Executive Report

Standard Preventive Calendar

Fortnightly: Module dry/wet cleaning cycle & visual string inspection
Monthly: Inverter filter cleaning, ACDB/DCDB thermal check & PR scorecard
Quarterly: Torque check on mounting structures, earthing ohm test & vegetation control
Annual: Full IR thermography scan, IV-curve diagnostics & transformer oil BDV testing
Predictive Energy Intelligence

AI-Powered Fault Detection & Energy Analytics

Traditional alarms only trigger when an inverter shuts down completely. Averon's AI models detect subtle 3–8% silent degradation long before hardware failure occurs.

  • ✓Soiling Loss Quantification: Calculates exact cleaning ROI so you wash panels at the optimal economic threshold.
  • ✓Silent String Anomaly Detection: Identifies bypassed diodes, PID, micro-cracks, and MC4 connector heating.
  • ✓Predictive Inverter Failure Warnings: Tracks IGBT temperature drift and derating signatures early.
Simulate AI Fault Detection
AI Diagnostics Output

Silent Losses Caught Automatically

Soiling Drift Warning-4.8% PR

Recommended cleaning window triggered 6 days earlier than fixed schedule.

DC String MismatchINV-03 / S4

32% current dip isolated under peak irradiance; fuse & connector check dispatched.

Inverter Clipping AnalysisOptimized

Reactive power tuning recovered 14.2 MWh annualized generation.

Need a Tailored Multi-Site SLA?

Let's Audit Your Solar Plant — Completely Free

Share your recent generation logs or invite our engineers on-site to uncover immediate yield recovery opportunities.